Fujitsu M10-4 Service Manual page 410

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

7.
Remove all the power cords from the SPARC M10-4S power supply unit
requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
25.3.2
System-stopped maintenance
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Power off all the physical partitions.
For details, see
6.
Execute the replacefru command to release the SPARC M10-4S requiring
maintenance from the system.
XSCF>   replacefru
For details, see
system."
7.
Remove all the power cords from the SPARC M10-4S power supply unit
requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
25.4
Removing a Crossbar Cable (Optical)
This section describes the procedure for removing the crossbar cables (optical).
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
386
"5.5.2 Removing the power
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.3 Powering Off the Physical Partition Requiring
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"5.5.2 Removing the power
cord."
Configuration."
Maintenance."
cord."

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents