Fujitsu M10-4 Service Manual page 257

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

#   cfgadm -c unconfigure  Ap_ID
6.
Execute the cfgadm(1M) command to blink the CHECK LED of the internal
disk requiring maintenance, and determine its location.
Enter the Ap_ID you noted in advance.
#   cfgadm -x led=fault,mode=blink  Ap_ID
7.
Execute the cfgadm(1M) command to confirm that the internal disk requiring
maintenance is disconnected.
The disconnected internal disk is displayed as "unconfigured."
#   cfgadm -a
12.3.2
Active/hot maintenance (with DR)
Note - Use the DR of the system board on a physical partition for active/cold maintenance.
For the XCP and Oracle VM Server for SPARC/SRU versions that correspond to the DR, see
the latest Product Notes.
Note - Active/hot maintenance (using DR) can be performed only for a building block
configuration.
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Release the chassis, in which the internal disk requiring maintenance is
mounted, from the physical partition.
For details, see
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.2 Releasing a Chassis from the Physical
Configuration."
Partition."
Chapter 12 Maintaining the Internal Disks
233

Advertisement