Understanding Types Of Maintenance - Fujitsu M10-4 Service Manual

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

1.
Log in to the XSCF shell.
2.
Execute the version command to determine the firmware version information.
In the following example, "-c xcp" is entered to determine the overall XCP version.
XSCF>   version -c xcp
4.3

Understanding Types of Maintenance

This section explains the types of maintenance.
The single-chassis configuration and building block configuration denote the
following system configurations.
Table 4-4     System configuration
Configuration
Single-chassis configuration
Building block configuration
There are the following five types of maintenance.
Active/hot maintenance
Maintenance work is performed while the physical partition remains turned on
and the input power to the chassis in which the target Field Replaceable Unit
(FRU) is mounted is on (power cord is connected). Active/hot maintenance can be
performed only on FRUs that have a redundant configuration or which support
PCI hot plugging (PHP).
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
44
Description
Configuration in which a single SPARC M10-4 or SPARC
M10-4S is used
Configuration in which 2 or more SPARC M10-4S's are
combined and used

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents