Fujitsu M10-4 Service Manual page 96

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Please execute   the   following   steps:
1)   Confirm   the   XSCF   STANDBY   LED   of   BB#0   is   not   lit.
2)   Turn   off   the   breaker   of   BB#0.
3)   Remove   BB#0.
4)   Execute   either   the   following:
    4-1)   After   the   exchanged   device   is   connected   with   the   system,
              turn   on   the   breaker   of   BB#0,   and   please   select   'finish'.
    4-2)   If   you   want   to   suspend   the   maintenance   without   exchanging   device,
              please   select   'cancel'.
[f:finish|c:cancel]   : f
The following screen is displayed. Wait until the processing has completed.
Waiting   for   BB#0   to   enter   install   state.
[This   operation   may   take   up   to   20   minute(s)]
(progress   scale   reported   in   seconds)
      0.....     30..   done
Waiting   for   BB#0   to   enter   ready   state.
[This   operation   may   take   up   to   45   minute(s)]
(progress   scale   reported   in   seconds)
      0.....     30.....     60.....   done
2.
After confirming that the FRU to be diagnosed is displayed, enter "s".
Do   you   want   to   start   to   diagnose   BB#0?[s:start|c:cancel]   : s
3.
After confirming again that the FRU to be diagnosed is displayed, enter "y".
Diagnostic   tests   for   BB#0   have   started.
Initial   diagnosis   is   about   to   start,   Continue?[y|n]   : y
The following is displayed. Wait until the processing is complete.
SB#00-0   power   on   sequence   started.
    0.....   30.....   60....end
Initial   diagnosis   started.   [1800sec]
    0.....   30.....   60.....   90.....120.....150.....180.....210.....240.....|
270.....300.....330.....360..end
Initial   diagnosis   has   completed.
SB   power   off   sequence   started.   [1200sec]
    0.....   30.....   60.....   90.....120....end
SB   powered   off.
PSB     Test         Fault
----   -------   --------
00-0   Passed     Normal    
done
4.
Confirm that the status is normal ("Normal") after the replacement, and then
enter "f".
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
72