Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] : f
The following screen is displayed. Wait until the processing has completed.
Waiting for BB#0 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30.. done
Waiting for BB#0 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... done
2.
After confirming that the FRU to be diagnosed is displayed, enter "s".
Do you want to start to diagnose BB#0?[s:start|c:cancel] : s
3.
After confirming again that the FRU to be diagnosed is displayed, enter "y".
Diagnostic tests for BB#0 have started.
Initial diagnosis is about to start, Continue?[y|n] : y
The following is displayed. Wait until the processing is complete.
SB#00-0 power on sequence started.
0..... 30..... 60....end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240.....|
270.....300.....330.....360..end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0..... 30..... 60..... 90.....120....end
SB powered off.
PSB Test Fault
---- ------- --------
00-0 Passed Normal
done
4.
Confirm that the status is normal ("Normal") after the replacement, and then
enter "f".
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014