5.1.2
Releasing an FRU of the crossbar box from the
system
If the maintenance target is a crossbar box, the following are targeted as FRUs:
Chassis of the crossbar box
■
Power supply unit of the crossbar box
■
Fan unit of the crossbar box
■
XSCF unit of the crossbar box
■
1.
Log in to the XSCF shell.
2.
Execute the replacefru command to display the maintenance menu.
XSCF> replacefru
3.
Select the FRU requiring maintenance by specifying it with a numeric key.
In the following example, since the crossbar box chassis itself is selected, "2" is
entered.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.
1. BB (4s Building Block Model)
2. XBBOX (XB-BOX Model)
------------------------------------------------------------------------------
Select [1,2|c:cancel] : 2
4.
Select the FRU requiring maintenance by specifying it with a numeric key.
In the following example, since XBBOX#81 is showing "Degraded" indicating
abnormality, "2" is entered.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select the chassis including replaced FRU.
No. FRU Status
--- ------------------- --------------
1 /XBBOX#80 Normal
2 /XBBOX#81 Degraded
------------------------------------------------------------------------------
Select [1,2|c:cancel] : 2
5.
Select the FRU requiring maintenance by specifying it with a numeric key.
In the following example, since the XSCF unit is selected as the maintenance
target, "3" is entered.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
56