Maintenance/Replacement Menu
Please select the BB or a type of FRU to be replaced.
1. BB itself
2. FAN (Fan Unit)
3. PSU (Power Supply Unit)
------------------------------------------------------------------------------
Select [1-3|c:cancel] : 1
6.
Select the faulty FRU by specifying it with a numeric key.
Since it was confirmed in step 4 that BB#0 is faulty, "1" is also entered here.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a FRU to be replaced.
No. FRU Status
--- ------------------- --------------
1 /BB#0 Degraded
------------------------------------------------------------------------------
Select [1|b:back] : 1
7.
After confirming that the selected FRU is displayed, enter "r".
You are about to replace BB#0.
Do you want to continue?[r:replace|c:cancel] : r
8.
Confirm that the CHECK LED of the FRU is on or blinking.
To release a SPARC M10-4S chassis itself, confirm that the system locator on the
chassis is blinking.
For details on the locations of LEDs, see
locator)" and
Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :
You can now start FRU maintenance. Do not enter "f" until you complete the
maintenance work.
"2.3.3 LEDs on each
component."
Chapter 5 Understanding the Preparations for Enabling Maintenance
"2.3.2 LEDs on the rear panel (System
55