5.
Execute the showstatus command to confirm that there is no problem with
the FRU after the completion of maintenance.
If there is no problem, nothing is displayed.
XSCF>   showstatus
6.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
Confirm that no asterisk (*) is displayed in front of each component.
XSCF>   showhardconf
7.
If the state of the master chassis requiring maintenance has been switched to
the standby state before maintenance, execute the switchscf command to
switch the chassis to the master XSCF.
XSCF>   switchscf -t Standby
8.
If you performed maintenance on a PCIe card using dynamic reconfiguration
(DR), restore the devices that were released before the maintenance to their
original configurations.
Reassign the devices that were released from the root domain and I/O domains.
#   ldm add-io PCIE8 domain01
#   ldm add-io PCIE9 domain01
#   ldm add-io PCIE10 domain01
#   ldm add-io PCIE11 domain01
#   ldm remove-io /BB1/PCI0 domain01  (*1)
#   ldm add-io /BB1/PCI0 iodomain  (*1)
*1: PCIe slots are automatically assigned to the root domain. Therefore, to
9.
Start the root domain and I/O domains.
If a virtual service is provided, the virtual service is automatically restarted.
Note - Start the root domain first, and then start I/O domains.
#   ldm start-domain domain01
#   ldm start-domain iodomain
10. If there is a guest domain that uses a virtual device, log in to the guest domain
to restart the use of the device or incorporate it into the duplication function
again.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
76
reassign them to I/O domains, they must be released and then reassigned.