mounted, from the physical partition.
For details, see
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
XSCF> replacefru
For details, see
system."
7.
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
7.3.2
Inactive/Cold maintenance
Note - See the procedure for system-stopped maintenance for inactive/cold maintenance in a
single-chassis configuration.
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF> showlogs error
For details, see
Note - When you add or remove CPU memory units, confirm that no error has occurred.
4.
Confirm the hardware and software configurations.
For details, see
5.
Power off the physical partition requiring maintenance.
For details, see
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
XSCF> replacefru
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
94
"5.2 Releasing a Chassis from the Physical
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"5.5.2 Removing the power
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.3 Powering Off the Physical Partition Requiring
Partition."
cord."
Configuration."
Maintenance."