2.
Carefully remove the fan unit from its slot.
Note - Place the removed fan unit on a grounded antistatic ESD mat.
11.5

Installing a Fan Unit

This section describes the procedure for installing a fan unit.
11.5.1
Installing a fan unit
1.
Carefully insert the fan unit into its slot.
Note - Do not force the fan unit into the slot. Using excessive force may damage the
component or the chassis.
2.
Push the fan unit fully home.
Note - Check that the fan unit is fully inserted and secured.
11.5.2

Restoring the chassis

1.
Install the front cover.
For details, see
11.6
Restoring the System
This section describes the procedure for restoring the system after installing a fan
unit. The restoration procedure differs depending on the maintenance type as follows:
Note - See the procedure for system-stopped maintenance for inactive/cold maintenance in a
single-chassis configuration.
Active/Hot maintenance
Inactive/Hot maintenance
"6.5.3 Installing the front
cover."
Chapter 11 Maintaining the Fan Units
219