/dev/chassis/SYS/BB1/CMUL/HDD1                                                             -
/dev/chassis/SYS/BB1/CMUL/HDD2                                                             -
/dev/chassis/SYS/BB1/CMUL/HDD3                                                             -
/dev/chassis/SYS/BB1/CMUL/HDD4                                                             -
/dev/chassis/SYS/BB1/CMUL/HDD5                                                             -
/dev/chassis/SYS/BB1/CMUL/HDD6                                                             -
/dev/chassis/SYS/BB1/CMUL/HDD7                                                             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD00/disk  
c4t50000394281B5312d0   <--   (1)
                                       *   The   last   four   digits   of   the   BB#1_CMUL  
serial   number
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD01/disk  
c4t50000394281B59D6d0   <--   (2)                               
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD02             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD03             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD04             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD05             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD06             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD07             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD00/disk  
c2t500003942823C8C6d0   <--   (3)
                                       *   The   last   four   digits   of   the   BB#0_CMUL  
serial   number
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD01/disk  
c2t50000394281B517Ad0   <--   (4)                           
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD02             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD03             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD04             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD05             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD06             -
/dev/chassis/FUJITSU-BBEXP.500000e0e06d237f/01Y1_HDD07             -  
Using the diskinfo command (Oracle Solaris 10)
1.
Execute the diskinfo command to check the physical disk slot and physical
system board.
(1) to (4) in the example below specify the following:
(1): The logical path name of the disk mounted on the HDD0.
(2): The device path of the disk mounted on the HDD0 of LSB#0.
(3): The logical path name of the disk mounted on the HDD1.
(4): The device path of the disk mounted on the HDD1 of LSB#0.
#   diskinfo -ap
 
Enclosure   path:                   2081210007-physical-hba-0
Chassis   Serial   Number:     2081210007-physical-hba-0
Chassis   Model:                     ORCL,SPARC64-X
 
Enclosure   path:                   /dev/es/ses0
Chassis   Serial   Number:     500000e0e06d233f
Chassis   Model:                     FUJITSU-BBEXP
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014