inserting the cable.
Note - If you insert a connector with the tab pulled, the connector may be damaged.
Note - Check that the crossbar cables (electrical) are correctly connected and secure.
24.6
Restoring the System
This section describes the procedure for restoring the system after installing the
crossbar cables (electrical). The restoration procedure differs depending on the
maintenance type as follows:
Inactive/Cold maintenance
System-stopped maintenance
24.6.1
Inactive/Cold maintenance
1.
Connect all the power cords to the PSU backplane unit of the chassis
requiring maintenance.
Note - In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the chassis has been incorporated into the system.
For details, see
the
3.
Execute the diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
01: BB-ID of the destination where the chassis to start the diagnosis is connected
(You can specify one or more of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
XSCF>   diagxbu -y -b 00 -t 01
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
378
For details, see
"6.5.1 Installing the power
"6.1.1 Incorporating an FRU of the SPARC M10-4/M10-4S into
system."
 
cord."