The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
01: BB-ID of the destination where the chassis to start the diagnosis is connected
(You can specify one or more of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
XSCF>   diagxbu -y -b 00 -t 01
4.
Execute the showlogs command to confirm that the system is operating
normally.
XSCF>   showlogs error
For details, see
"3.3.5 Checking log
5.
Start the entire system.
For details, see
"6.4 Starting the Entire
6.
Close the rack door.
information."
System."
Chapter 14 Maintaining the PSU Backplane Unit
281