XSCF> diagxbu -y -b 00 -t 01
- When the system board of the chassis connected with the crossbar cables
XSCF> diagxbu -y -b 00 -p 02
3.
Execute the showlogs command to confirm that the system is operating
normally.
XSCF> showlogs error
For details, see
4.
Start the entire system.
For details, see
5.
Close the rack door.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
348
connected (You can specify more than one of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
is incorporated into the physical partition, and the physical partition is
powered on:
The example below specifies the following:
00: The BB-ID of the chassis to start the diagnosis
02: The PPAR-ID of the destination where the chassis to start the diagnosis is
connected (You can specify only one of these.)
"3.3.5 Checking log
"6.4 Starting the Entire
information."
System."