Mitsubishi Electric FR-E700 Instruction Manual page 580

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Common specifications
FR-E700SC
Operating status
Operation panel
or
Parameter unit (FR-PU07)
Fault record
Operating status
Additional display by the
Fault record
parameter unit
(FR-PU04/FRPU07) only
Interactive guidance
Protective functions
Warning functions
Ambient temperature
Storage temperature
Ambient humidity
Ambience conditions
Altitude
Vibration resistance
Tab. A-3:
Common specifications (2)
This operation guide is only available with option parameter unit (FR-PU07).
This protective function is available with the three-phase power input specification model only.
This protective function does not function in the initial status.
When using the inverters at the ambient temperature of 40 °C or less, the inverters can be installed
closely attached (0 cm clearance).
The product may only be exposed to the full extremes of this temperature range for short periods
(e.g. during transportation).
A - 4
Specification
The following operating status can be displayed: output frequency, motor current (steady), output voltage, frequency setting,
cumulative energization time, actual operation time, motor torque, converter output voltage, regenerative brake duty,
electronic thermal relay function load factor, output current peak value, converter output voltage peak value, motor load
factor, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor, I/O terminal option monitor, output
power, cumulative power, motor thermal load factor, and inverter thermal load factor.
Fault record is displayed when a fault occurs.
Past 8 fault records (output voltage/current/frequency/cumulative energization time right before the fault occurs) are stored.
Not used
Output voltage/current/frequency/cumulative energization time immediately before the fault occurs
Operation guide/trouble shooting with a help function
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during
acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation,
motor protection thermal operation, heatsink overheat, input phase failure , output side earth (ground) fault overcurrent at
start, output phase failure, external thermal relay operation , option fault , parameter error, internal board fault, PU
disconnection, retry count excess , CPU fault, brake transistor alarm, inrush resistance overheat, communication error,
analog input error, USB communication error, brake sequence error 4 to 7 , safety circuit fault
Fan alarm (FR-E720S-050SC or more, FR-E740-040SC or more), overcurrent stall prevention, overvoltage stall prevention, PU
stop, parameter write error, regenerative brake prealarm , electronic thermal relay function prealarm, maintenance
output , undervoltage, operation panel lock, password locked, inverter reset, safety stop
10 °C to +50 °C (non-freezing)
20 °C to +65 °C
Max. 90% (non-condensing)
For indoor use only, avoid environments containing corrosive gases, install in a dust-free location.
Max. 1000 m above sea level
Max. 5.9 m/s² (JIS 60068-2-6) or less at 10 to 55 Hz (directions of X, Y and Z axes)
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents