Mitsubishi Electric FR-E700 Instruction Manual page 183

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
Parameter
Func-
Name
tion
,
Ethernet IP address 1
805
,
Ethernet IP address 2
806
,
Ethernet IP address 3
807
,
Ethernet IP address 4
808
,
Subnet mask 1
809
,
Subnet mask 2
810
,
Subnet mask 3
811
,
Subnet mask 4
812
Ethernet communication
,
830
network number
Ethernet communication
,
831
station number
Link speed and duplex mode
,
832
selection
,
Ethernet function selection 1
833
,
Ethernet function selection 2
834
,
Ethernet function selection 3
835
,
Ethernet IP filter address 1
837
,
Ethernet IP filter address 2
838
,
Ethernet IP filter address 3
839
,
Ethernet IP filter address 4
840
Ethernet IP filter address 2
,
841
range specification
Ethernet IP filter address 3
,
842
range specification
Ethernet IP filter address 4
,
843
range specification
Ethernet command source
,
844
selection IP address 1
Ethernet command source
,
845
selection IP address 2
Ethernet command source
,
846
selection IP address 3
Ethernet command source
,
847
selection IP address 4
Ethernet command source
,
selection IP address 3 range
848
specification
Ethernet command source
,
selection IP address 4 range
849
specification
Tab. 6-1:
Parameter overview (29)
This setting is only available for the FR-E700 SC ENE.
The setting is applied after an inverter reset or power-ON.
These parameters are communication parameters that are not cleared when parameter clear (All
parameter clear) is executed from Ethernet network (MODBUS®/TCP or CC-Link IE Field Network
Basic).
(Refer to page 6-333 for the details of the MODBUS®/TCP, and page 6-349 for the details of the CC-
Link IE Field Network Basic.)
FR-E700 SC EC/ENE
Incre-
Initial
Setting
ments
Value
Range
1
192
0–255
1
168
0–255
1
50
0–255
1
1
0–255
1
255
0–255
1
255
0–255
1
255
0–255
1
0
0–255
1
1
1–239
1
1
1–120
1
0
0–4
1
31
0, 10, 20, 30,
1
20
31, 36, 38, 9999 Set the application, protocol, etc.
1
9999
1
0
0–255
1
0
0–255
1
0
0–255
1
0
0–255
1
9999
0–255, 9999
1
9999
0–255, 9999
1
9999
0–255, 9999
1
0
0–255
1
0
0–255
1
0
0–255
1
0
0–255
1
9999
0–255, 9999
1
9999
0–255, 9999
Description
Enter the IP address of the inverter to be
connected to Ethernet.
Enter the subnet mask of the network to
which the inverter belongs
Enter the network number.
Enter the station number.
Set the communication speed and the
communication mode (full-duplex/half-
duplex).
Set the range of connectable IP addresses for
the network devces.
(When Pr. 837 to Pr. 840 = "0 (initial value)",
the function is invalid.)
To limit the network devices that send the
operation or speed command through the
Ethernet network (MODBUS®/TCP or CC-Link
IE Field Network Basic), set the range of IP
addresses of the devices.
When Pr. 844 to Pr.847 = "0 (initial value)",
no IP address is specified for sending
commands through the Ethernet network. In
this case, operation through the Ethernet
network (MODBUS®/TCP or CC-Link IE Field
Network Basic) is not available.
When four or more clients attempt a
connection to the inverter during MODBUS®/
TCP communication, the connection
attempted from outside of the IP address
range set for Ethernet command source
selection may be forcibly closed.
Parameter overview
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled
6-283
6 - 29