CC-Link IE Field Network Basic
Item
Faults history
batch clear
Parameter clear
All parameter
clear
Inverter reset
Link parameter
extended
setting
Second parame-
ter changing
Tab. 6-161: Setting of the instruction codes and data (2)
When "100" is set in Pr. 52 Operation panel main monitor selection, frequency setting is moni-
tored during a stop and output frequency is monitored during running.
Write data is in hexadecimal, and only last two digits are valid. (The upper two digits are ignored.)
Setting from the remote register (RWw1) is also available.
Turning OFF the power supply while clearing parameters with H5A5A or H55AA sets back the
communication parameter settings to the initial settings.
Setting is valid only when Pr. 544 = "0". When Pr. 544 "0", set using RWw2 or RWw10, 12, 14, 16,
or 18. (Refer to page 6-358)
Reading or writing is available when the link parameter extended setting = "1 or 9".
Gain frequencies can be written using Pr. 125 (instruction code H99) and Pr. 126 (instruction code
H9A) also.
NOTE
When the 32-bit parameter setting or monitor description are read and the read value exceeds
HFFFF, the reply data will be HFFFF.
6 - 362
Read/
Instruc-
tion code Description
write
Write
HF4
H9696: Clears the faults history as a batch.
All parameters return to the initial values.
Whether to clear communication parameters or not can be selected according
to data.
Parameter clear
H9696: Communication parameters are cleared
H5A5A: Communication parameters are not cleared
All parameter clear
H9966: Communication parameters are cleared
Write
HFC
H55AA: Communication parameters are not cleared
For more information about parameter clear, all clear, and communication
parameters refer to page A-16.
When clear is executed for H9696 or H9966, communication-related parame-
ter settings also return to the initial values. When resuming operation, set the
parameters again. Executing clear will clear the instruction code HEC, HF3,
and HFF settings.
Write
HFD
H9696: Resets the inverter.
H00 to H0D: Parameter description is changed according to the instruction
Read
H7F
code (extended) setting.
For more information about the instruction codes refer to the parameter list
Write
HFF
on page A-16.
Read or write of bias and gain parameters (instruction codes H5E to H61 and
Read
H6C
HDE to HE1 with the link parameter extended setting = "1", H11 to H23 and
H91 to HA3 with the link parameter extended setting = "9").
H00: Frequency
Write
HEC
H01: Analog value set in parameters
H02: Analog value input from the terminal
Parameter