Simple mode parameter list
Monitor display during auto tuning
Monitor is displayed on the operation panel and parameter unit (FR-PU04/FR-PU07) during tuning as
below. The value displayed corresponds to the value of parameter 96.
Parameter 96
Setting
Tuning in
progress
Normal end
Error end (when
inverter protec-
tive function
operation is acti-
vated)
Tab. 5-4:
NOTE
The set frequency monitor displayed during the offline auto tuning is 0 Hz.
Reference: Offline auto tuning time (when the initial value is set)
Offline Auto Tuning Setting
Tune all motor constants (Pr. 96 = 1)
Tune motor constants (R1) only (Pr. 96 = 11)
Tab. 5-5:
Return to the normal operation mode
When offline auto tuning ends, press the STOP/RESET key of the operation panel during PU operation.
For external operation, turn off the start signal (STF signal or STR signal) once.
This operation resets the offline auto tuning and the PU's monitor display returns to the normal in-
dication. (Without this operation, next operation cannot be started.)
NOTE
Do not change the Pr. 96 setting after completion of tuning (3 or 13). If the Pr. 96 setting is
changed, tuning data is made invalid. If the Pr. 96 setting is changed, tuning must be performed
again.
5 - 18
Parameter Unit
(FR-PU04/FR-PU07) Display
1
11
READ:List
READ:List
1
STOP
PU
STOP
TUNE
TUNE
2
STF
FWD
PU
STF
FWD PU
TUNE
TUNE
3
COMPLETION
COMPETION
STF
STOP PU
STF
STOP PU
TUNE
9
ERROR
STF
STOP PU
Monitor display
Offline auto tuning time (when the initial value is set)
Operation Panel Indication
1
11
PU
12
Flickering
13
Time
Approximately 25 to 75 s
(Tuning time differs according to the inverter capacity and
motor type.)
Approximately 9 s
Basic settings
11
Flickering