Parameter overview
Parameter
Func-
Name
tion
503
Maintenance timer
Maintenance timer alarm
504
output set time
Frequency command sign
541
selection
,
CC-Link extended setting
544
USB communication station
547
number
USB communication check
548
time interval
Refer to Pr. 338 to Pr. 339
551
549
Refer to Pr. 117 to Pr. 124
550
Refer to Pr. 338 and Pr. 339
551
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
563
Refer to Pr. 52
564
571
Refer to Pr. 13
611
Refer to Pr. 57
645
Refer to Pr. C1 (901)
653
Speed smoothing control
665
Refer to Pr. 882
800
Refer to Pr. 80
Tab. 6-1:
Parameter overview (28)
This setting is only available for the FR-E700 SC ENE.
The setting is applied after an inverter reset or power-ON.
These parameters are communication parameters that are not cleared when parameter clear (all
clear) is executed from RS-485 communication.
(Refer to section 6.19 for RS-485 communication.)
6 - 28
Incre-
Initial
Setting
ments
Value
Range
1
0
0 (1–9998)
0–9998
1
9999
9999
1
0
0, 1
1
0
0, 1, 12, 14, 18
1
0
0–31
0
0.1 s
9999
0.1–999.8 s
9999
0.1 s
1 s
0.1–1.0 s
0.1 s
0 s
0.0–20.0 s
Rated
0.01 A
inverter cur-
0–500 A
rent
0.1%
0
0–200%
Description
Display the cumulative energizing time of
the inverter in 100h increments. Reading
only
Writing the setting of "0" clears the
cumulative energizing time.
Set the time taken until when the
maintenance timer alarm output signal
(Y95) is output.
No function
The start command (forward/reverse
rotation) can be inverted by adding a plus or
minus sign to the value of the frequency
command.
Use this parameter to select the function of
the remote registers for the CC-Link IE Field
Network Basic.
Specifies the inverter station number.
USB communication is enabled. However,
the inverter will come to an alarm stop
(E.USB) if operation is changed to PU
operation mode.
Set the interval of communication check
time.
No communication check
Set the time taken to average the current
during start bit output (1 s).
Set the time for not obtaining (mask)
transient state data.
Set the reference (100%) for outputting the
signal of the current average value
The torque fluctuation is reduced to reduce
vibration due to mechanical resonance.
Parameter
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Clear
Refer
to
Page
✔: Enabled
—: Disabled
6-323
6-349
6-292
6-324
6-176