Mitsubishi Electric FR-E700 Instruction Manual page 524

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

CC-Link IE Field Network Basic
Parameter writing
The following program changes the setting of Pr. 7 "Acceleration time" of station 1 inverter to 3.0 s.
● Acceleration time writing instruction code: H87 (hexadecimal)
● Acceleration time set data: K30 (decimal)
For information about the instruction codes refer to the parameter list on page A-16.
The reply code at the time of instruction code execution is set to D2.
(For information about the reply code (RWr2) refer to page 6-360.)
SM1536
SD1536.0
SD1540.0
(0)
M0
X20
(4)
M300
(8)
M301
X100F
(10)
M302
X100F
(19)
(25)
Fig. 6-182: Program example 6
NOTES
For parameters having numbers 100 and later, change their link parameter extended settings (set
them to other than H00). Refer to page A-16 for details.
For other functions, refer to the instruction codes on page 6-361.
6 - 370
M0
Check the data link status of the station 1
PLS
M300
SET
M301
MOV
H87
W102
Write Pr.7 write (H87) to RWw2 and acceleration
time setting data (K30) to RWw3.
MOV
K30
W103
Turn on the instruction code execution request
SET
Y100F
(RY0F)
RST
M301
SET
M302
Read reply code (RWr2) to D2 when the instruction
MOV
W2
D2
code execution completion (RX0F) turns on.
RST
Turn off the instruction code execution request
Y100F
(RY0F)
RST
M302
END