Operation panel
Screen at powering on
The monitor display appears.
Press the PU/EXT key to choose the PU
operation mode.
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until P.161 (Pr. 161) appears.
Press the SET key to show the currently set value.
The initial value "0" appears.
Turn the digital dial clockwise to change it
to the setting value of "10".
Press the SET key to set.
Press the MODE key for 2 s to show the key lock
mode.
Fig. 4-9:
4 - 14
Operation
Operation lock
Operation
Display
PU indication is lit.
PRM indication is lit.
The parameter number read previously
appears.
Flicker ... Parameter setting complete!