Mitsubishi Electric FR-E700 Instruction Manual page 176

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
RUN terminal function
190
selection
191
FU terminal function selection
ABC terminal function
192
selection
232
Refer to Pr. 4 to Pr. 6
239
240
Refer to Pr. 72
241
Refer to Pr. 125 and Pr. 126
Tab. 6-1:
Parameter overview (22)
6 - 22
Incre-
Initial
Setting
ments
Value
Range
0/1/3/4/7/8/
11–16/20/25/
1
0
26/46/47/64/
80/81/90/91/
93/95/96/98/
99/100/101/
103/104/107/
108/111–116/
120/125/126/
146/147/164/
180/181/190/
191/193/195/
1
4
196/198/199/
9999
0/1/3/4/7/8/
11–16/20/25/
26/46/47/64/
80/81/90/91/
95/96/98/99/
100/101/103/
1
99
104/107/108/
111–116/120/
125/126/146/
147/164/180/
181/190/191/
195/196/198/
199/9999
Description
0/100:
Inverter running
1/101:
Up to frequency
3/103:
Overload alarm
4/104:
Output frequency detection
7/107:
Regenerative brake pre-alarm
8/108:
Electronic thermal relay
function pre-alarm
11/111:
Inverter operation ready
12/112:
Output current detection
13/113:
Zero current detection
14/114:
PID lower limit
15/115:
PID upper limit
16/116:
PID forward/reverse
rotation output
20/120:
Brake opening request
25/125:
Fan fault output
26/126:
Heatsink overheat pre-alarm
46/146:
During deceleration at
occurrence of power failure
(retained until release)
47/147:
PID control activated
64/164:
During retry
80/180:
Safety monitor output
81/181:
Safety monitor output 2
90/190:
Life alarm
91/191:
Alarm output 3
(power-off signal)
93/193:
Current average monitor
95/195:
Maintenance timer alarm
96/196:
Remote output
98/198:
Minor fault output
99/199:
Alarm output
9999:
No function
0–99:
Source logic
100–199: Sink logic
Parameter
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled
6-126

Hide quick links:

Advertisement

Table of Contents