General-Purpose Magnetic Flux Vector Control - Mitsubishi Electric FR-E700 Instruction Manual

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
6.3.3

General-purpose magnetic flux vector control

(Pr. 71, Pr. 80, Pr. 81, Pr. 800)
General-purpose magnetic flux vector control is the same function as the FR-E500 series. Select this
control when the same operation characteristic is necessary. For other cases, select advanced mag-
netic flux vector control.
Pr. No. Name
Initial Value
71
Applied motor
80
Motor capacity
9999
Number of motor
81
9999
poles
Control method
800
selection
The above parameters can be set when Pr. 160 "User group read selection" = 0.
Set a value other than "9999" in Pr. 80 and Pr. 81.
If the following conditions are not satisfied, select V/F control since malfunction such as insufficient
torque and uneven rotation may occur.
● The motor capacity should be equal to or one rank lower than the inverter capacity.
● Motor to be used is any of Mitsubishi standard motor, high efficiency motor (SF-JR, SF-HR 0.2 kW
or more) or Mitsubishi constant-torque motor (SF-JRCA four-pole, SF-HRCA 0.2 kW to 15 kW).
When using a motor other than the above (other manufacturer's motor), perform offline auto
tuning without fail.
● Single-motor operation (one motor run by one inverter) should be performed.
● The wiring length from inverter to motor should be within 30 m. (Perform offline auto tuning in
the state where wiring work is performed when the wiring length exceeds 30 m.)
● Permissible wiring length between inverter and motor differs according to the inverter capacity
and setting value of Pr. 72 "PWM frequency selection" (carrier frequency) (refer to page 3-13).
FR-E700 SC EC/ENE
Setting Range
Description
By selecting a standard motor or constant torque motor,
0/1/3–6/13–16/23/24/
0
thermal characteristic and motor constants of each motor
40/43/44/50/53/54
are set.
0.1–15 kW
Applied motor capacity.
9999
V/F control
2/4/6/8/10
Number of motor poles.
9999
V/F control
20
Advanced magnetic flux vector control
20
30
General-purpose magnetic flux vector control
Adjust the output torque (current) of the motor
GP MFVC
GP MFVC
GP MFVC
Refer to
Parameters referred to
Section
3
Base frequency
6.5.1
19
Base frequency
6.5.1
71
Applied motor
6.8.2
77
Parameter write
6.17.2
selection
6 - 41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents