Mitsubishi Electric FR-E700 Instruction Manual page 150

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

External operation
5.3.4
Change the frequency (40 Hz) of the maximum value of potentiometer (at 5 V)
Example
The frequency of the maximum analog voltage of the potentiometer (at 5 V) has to be changed
from the initial setting of 50 Hz to 40 Hz. Set 40 Hz in Pr. 125.
Turn the digital dial until P.125 (Pr. 125) appears.
Press the SET key to show the currently set value.
The initial value "50.00" (50.00 Hz) appears.
Turn the digital dial to change the set value to
"40.00" (40.00 Hz).
Press the SET key to set.
Press the MODE key twice to choose monitor/
frequency monitor.
Turn the start switch (STF or STR) on and turn the
volume (frequency setting potentiometer)
clockwise to full slowly. (Refer to Fig. 5-27,
step
Fig. 5-28: Change the frequency of the maximum analog value
NOTES
Set the frequency at 0 V using calibration parameter C2.
As other adjustment methods of frequency setting voltage gain, there are methods to adjust with
a voltage applied to across terminals 2-5 and adjust at any point without a voltage applied. (Refer
to section 6.16.3 for the setting method of calibration parameter C4.)
5 - 38
Operation
to
).
Initial value
50 Hz
Bias
C2 (Pr. 902)
0
Frequency setting signal
0
0
C3 (Pr. 902)
Gain
Pr. 125
100%
5 V
10 V
C4 (Pr. 903)
Basic settings
Display
Flicker ... 40Hz output at 5V
input complete!
I001780E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents