Parameter overview
Parameter
Func-
Name
tion
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
Motor constant (R1)
90
Motor constant (R2)
91
Motor constant (L1)
92
Motor constant (L2)
93
Tab. 6-1:
Parameter overview (14)
6 - 14
Incre-
Initial
Setting
ments
Value
Range
0–500 A *
0.01 A *
9999
9999
200 V/
0.1 V
0–1000 V
400 V *
0.01 Hz
50 Hz
10–120 Hz
0–50
*
0.001 *
9999
9999
0–50
*
0.001 *
9999
9999
0–1000 mH *
0.1 mH *
9999
9999
0–1000 mH *
0.1 mH *
9999
9999
Description
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to the
Pr. 71 setting.
Uses the Mitsubishi motor (SF-JR, SF-HRCA)
constants
Set the rated motor voltage (V).
* The initial value differs according to the
voltage class: 200 V/400 V
Set the rated motor frequency (Hz).
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
Parameter
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled