Parameter overview
Parameter
Func-
Name
tion
DC injection brake operation
10
frequency
DC injection brake operation
11
time
DC injection brake operation
12
voltage
13
Starting frequency
Holding time at a start
571
14
Load pattern selection
15
Jog frequency
Jog acceleration/
16
deceleration time
17
MRS input selection
18
Refer to Pr. 1 and Pr. 2
19
Refer to Pr. 3
20
Refer to Pr. 7 and Pr. 8
21
Tab. 6-1:
Parameter overview (4)
6 - 4
Incre-
Initial
Setting
ments
Value
Range
0.01 Hz
3Hz
0–120 Hz
0
0.1 s
0.5s
0.1–10 s
0
0.1%
6/4/2% *
0.1–30 %
0.01 Hz
0.5Hz
0–60 Hz
0.0–10.0 s
0.1 s
9999
9999
0
1
1
0
2
3
0.01 Hz
5Hz
0–400 Hz
0.1/
0–3600/
0.5s
0.01 s
360 s
0
2
1
0
4
Description
Set the operation frequency of the DC
injection brake.
DC injection brake disabled
Set the operation time of the DC injection
brake.
DC injection brake disabled
Set the DC injection brake voltage (torque).
* Initial values differ according to the inverter
capacity:
FR-E720S-008SC and 015SC/
FR-E720S-030SC to 110SC,
FR-E740-016SC to 170SC/
FR-E740-230SC and 300SC
Starting frequency can be set.
Set the holding time of Pr. 13 "Starting
frequency".
Holding function at start is invalid.
For constant torque load
For variable-torque load
at reverse rotation
boost of 0%
For constant
torque elevators
at forward rotation
boost of 0%
Set the frequency for jog operation.
Set the acceleration/deceleration time for
jog operation. Set the time taken to reach
the frequency set in Pr. 20 "Acceleration/
deceleration reference frequency" for
acceleration/deceleration time (initial value
is 50 Hz).
In addition, acceleration/deceleration time
can not be set separately.
Open input always
Normally closed input
(NC contact input specifications)
External terminal: Normally closed input
(NC contact input specifications)
Communication: Normally open input
Parameter
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled
6-100
6-75
6-58
6-63
6-119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents