Parameter
PU operation mode (Pr. 79 = 1)
Select the PU operation mode when applying start and speed command by only the key operation of
the operation panel (FR-PU04/FR-PU07). Also select the PU operation mode when making commu-
nication using the PU connector.
When "1" is selected for Pr. 79, the inverter enters the PU operation mode at power on. You cannot
change to the other operation mode.
The setting dial of the operation panel can be used for setting like a volume. (Pr. 161 "Frequency set-
ting/key lock operation selection", refer to section 6.22.3).
FR-E700 SC EC/ENE
Inverter
Operation panel
Selection of operation mode and operation location
Fig. 6-106:
PU operation mode
I001825E
6 - 211