Parameter
Parameter
Func-
Name
tion
7
Acceleration time
8
Deceleration time
Acceleration/deceleration
20
reference frequency
Acceleration/deceleration
21
time increments
Second acceleration/
44
deceleration time
Second deceleration time
45
Acceleration/deceleration
147
time switching frequency
9
Electronic thermal O/L relay
Second electronic
51
thermal O/L relay
Tab. 6-1:
Parameter overview (3)
FR-E700 SC EC/ENE
Incre-
Initial
Setting
ments
Value
Range
0.1/
0–3600/
5/10/15 s *
0.01 s
360 s
0.1/
0–3600/
5/10/15 s *
0.01 s
360 s
0.01 Hz
50 Hz
1–400 Hz
0
1
0
1
0.1/
5/10/
0–3600/
0.01 s
15 s *
360 s
0–3600/
0.1/
360 s
9999
0.01 s
9999
0–400 Hz
0.01 Hz
9999
9999
Rated
0.01 A
inverter out-
0–500 A
put current *
0–500 A
0.01 A
9999
9999
Description
Set the motor acceleration time
* Initial values differ according to the inverter
capacity:
FR-E720S-110SC or less,
FR-E740-095SC or less/
FR-E740-120SC and 170SC/
FR-E740-230SC and 300SC
Set the motor deceleration time
* Initial values differ according to the inverter
capacity:
FR-E720S-110SC or less,
FR-E740-095SC or less/
FR-E740-120SC and 170SC/
FR-E740-230SC and 300SC
Set the frequency referenced as
acceleration/deceleration time. As
acceleration/deceleration time, set the
frequency change time from stop to Pr. 20.
Increments:
0.1 s
Increments and setting
Range:
range of acceleration/
0–3600 s
deceleration time
Increments:
setting can be
0.1 s
changed.
Range:
0–3600 s
Set the acceleration/deceleration time when
the RT signal is on.
* Initial values differ according to the inverter
capacity:
FR-E720S-110SC or less,
FR-E740-095SC or less/
FR-E740-120SC and 170SC/
FR-E740-230SC and 300SC
Set the deceleration time when the RT signal
is on.
Acceleration time = deceleration time
Frequency when automatically switching to
the acceleration/deceleration time of Pr. 44
and Pr. 45.
No function
Set the rated motor current.
* The initial value of the 026SC or less is set to
85% of the rated inverter current.
Made valid when the RT signal is on. Set the
rated motor current.
Second electronic thermal O/L relay invalid
Parameter overview
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled
6-71
6-82
6 - 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents