Parameter
Operation is performed at the frequency set in Pr. 4 when the RH signal turns on, Pr. 5 when the RM sig-
nal turns on, and Pr. 6 when the RL signal turns on.
Frequency from speed 4 to speed 15 can be set according to the combination of the RH, RM, RL and
REX signals. Set the running frequencies in Pr. 24 to Pr. 27, Pr. 232 to Pr. 239. (In the initial value setting,
speed 4 to speed 15 are unavailable.)
Fig. 6-18: Multi-speed selection by external terminals
When "9999" is set in Pr. 232 "Multi-speed setting (speed 8)", operation is performed at fre-
quency set in Pr. 6 when RH, RM and RL are turned off and REX is turned on.
NOTES
In the initial setting, if two or three speeds are simultaneously selected, priority is given to the set
frequency of the lower signal. For example, when the RH and RM signals turn on, the RM signal
(Pr. 5) has a higher priority.
The RH, RM, RL signals are assigned to the terminal RH, RM, RL in the initial setting. By setting "0
(RL)", "1 (RM)", "2 (RH)" in any of Pr. 178 to Pr. 184 "Input terminal function assignment", you can
assign the signals to other terminals.
For the terminal used for REX signal input, set "8" in any of Pr. 178 to Pr. 184 to assign the function.
FR-E700 SC EC/ENE
Speed 1 (high speed)
Speed 2 (middle speed)
Speed 3 (low speed)
time
ON
ON
ON
Speed 5
Speed 6
Speed 4
Speed 7
ON
ON
ON
ON
ON
ON
ON
ON
Frequency setting by external terminals
Fig. 6-17:
Multi-speed selection by external terminals
Speed 10
Speed 11
Speed 12
Speed 9
Speed 8
ON
ON
ON ON
ON
ON
ON
ON
ON ON ON
ON
ON ON ON
a
Speed 13
Speed 14
Speed 15
time
ON
ON
ON ON
ON
I002062E
I002063E
6 - 61