Parameter
● When Pr. 544 = "18" (compatible with the octuple setting of CC-Link Ver.2)
– Remote I/O (32 points (128 points occupied))
Same as when Pr. 544 = 0 (Refer to page 6-351.)
– Remote register
Description
Address
Upper 8 bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01 Hz increments)
Link parameter
RWwn+2
extended setting
RWwn+3
Write data
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
RWwn+8
Faults history No.
RWwn+9
PID set point (0.01 % increments)
RWwn+A
PID measured value (0.01 % increments)
RWwn+B
PID deviation (0.01 % increments)
RWwn+C
RWwn+D
RWwn+E
RWwn+F
Link parameter
RWwn+10
extended setting
RWwn+11
Write data
Link parameter
RWwn+12
extended setting
RWwn+13
Write data
Link parameter
RWwn+14
extended setting
RWwn+15
Write data
Link parameter
RWwn+16
extended setting
RWwn+17
Write data
Link parameter
RWwn+18
extended setting
RWwn+19
Write data
RWwn+1A
RWwn+1B
RWwn+1C
RWwn+1D
RWwn+1E
RWwn+1F
Tab. 6-154:
Remote write register
Valid when Pr. 128 = "50, 51, 60, or 61".
When Pr. 37 is not equal to "0", this will be machine speed display (1 increments).
"n" indicates a value determined according to the station number setting.
FR-E700 SC EC/ENE
Refer to
page
Lower 8 bits
Monitor code 1
6-358
6-358
Instruction code
6-358
6-358
6-358
6-358
6-358
6-358
H00
6-358
6-358
6-358
6-358
H00 (Free)
Instruction code
6-358
6-358
Instruction code
6-358
6-358
Instruction code
6-358
6-358
Instruction code
6-358
6-358
Instruction code
6-358
6-358
H00 (Free)
Address
Upper 8 bits
RWrn
RWrn+1
RWrn+2
Reply code 2
RWrn+3
RWrn+4
RWrn+5
RWrn+6
RWrn+7
RWrn+8
Faults history No.
RWrn+9
RWrn+A
RWrn+B
RWrn+C
RWrn+D
RWrn+E
RWrn+F
RWrn+10
RWrn+11
RWrn+12
RWrn+13
RWrn+14
RWrn+15
RWrn+16
RWrn+17
RWrn+18
RWrn+19
RWrn+1A
RWrn+1B
RWrn+1C
RWrn+1D
RWrn+1E
RWrn+1F
Tab. 6-155:
CC-Link IE Field Network Basic
Description
Lower 8 bits
First monitor value
Second monitor value
Reply code 1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Fault data
Fault record (output frequency)
Fault record (output current)
Fault record (output voltage)
Fault record (energization time)
H00 (Free)
Reply code
Read data
Reply code
Read data
Reply code
Read data
Reply code
Read data
Reply code
Read data
H00 (Free)
Remote read register
Refer to
page
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6-359
6 - 355

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents