Mitsubishi Electric MELSEC iQ-R Series User Manual page 75

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Setting the set value (SV) and the setting variation rate limiter
The following figures show the relation of two set values (SV) depending on whether a setting variation rate limiter has been
set or not.
• When the setting variation rate limiter has not been set: The two set values (SV) are the same.
Temperature process value (PV)
Set value (SV) 2
Change
Set value (SV) 1
0
(1) "Target Value(SV) Setting" of "Control basic parameters" in "Application Setting" and 'CH1 Set value (SV) monitor' (Un\G406)
• When a setting variation rate limiter has been set: The value in 'CH1 Set value (SV) monitor' (Un\G406) follows the set
value (SV) after the setting.
Temperature process value (PV)
Set value (SV) 2
Change
Set value (SV) 1
0
(1) "Target Value(SV) Setting" of "Control basic parameters" in "Application Setting"
(2) 'CH1 Set value (SV) monitor' (Un\G406)
(3) "Setting change rate limiter" of "Limiter setting" in "Application Setting"
(4) "Setting change rate limiter unit time setting" of "Limiter setting" in "Application Setting"
(1)
Time
(1)
(2)
(3)
Time
(4)
1 FUNCTIONS
73
1.25 Alert Function