CH1 Rate alarm upper limit value
Set the rate alarm upper limit value.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory area name
CH Rate alarm upper limit value
CH Rate alarm upper limit value (in the Q compatible mode)
■Setting range
The setting range is -32768 to 32767.
■Setting unit
The value to be set differs depending on the value stored in 'CH1 Decimal point position' (Un\G400).
• No decimal point (0): Set a value in increments of 1 ( or digit).
• First decimal place (1): Set a value (the value multiplied by 10) in increments of 0.1 ().
■Enabling the settings
Turn ON and OFF 'Setting change command' (YB) in the setting mode ('Setting/operation mode status' (X1): OFF) to enable
the settings.
■Default value
The default value is 0.
CH1 Rate alarm lower limit value
Set the rate alarm lower limit value. For details on this area, refer to the following:
Page 292 CH1 Rate alarm upper limit value
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory area name
CH Rate alarm lower limit value
CH Rate alarm lower limit value (in the Q compatible mode)
APPX
292
Appendix 3 Buffer Memory Areas
CH1
CH2
541
741
203
219
CH1
CH2
542
742
204
220
CH3
CH4
941
1141
235
251
CH3
CH4
942
1142
236
252