CH1 Rate alarm upper limit value
Set the rate alarm upper limit value.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory area name
CH Rate alarm upper limit value
CH Rate alarm upper limit value (in the Q compatible mode)
■Setting range
The setting range is -32768 to 32767.
■Setting unit
The value to be set differs depending on the value stored in 'CH1 Decimal point position' (Un\G400).
• No decimal point (0): Set a value in increments of 1 ( or digit).
• First decimal place (1): Set a value (the value multiplied by 10) in increments of 0.1 ().
■Enabling the settings
Turn ON and OFF 'Setting change command' (YB) in the setting mode ('Setting/operation mode status' (X1): OFF) to enable
the settings.
■Default value
The default value is 0.
CH1 Rate alarm lower limit value
Set the rate alarm lower limit value. For details on this area, refer to the following:
Page 292 CH1 Rate alarm upper limit value
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory area name
CH Rate alarm lower limit value
CH Rate alarm lower limit value (in the Q compatible mode)
APPX
292
Appendix 3 Buffer Memory Areas
CH1
CH2
541
741
203
219
CH1
CH2
542
742
204
220
CH3
CH4
941
1141
235
251
CH3
CH4
942
1142
236
252