Mitsubishi Electric MELSEC iQ-R Series User Manual page 208

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
777(309H)
CH4
Derivative action
selection
778(30AH)
CH4
Simultaneous
temperature rise
group setting
779(30BH)
CH4
Simultaneous
temperature rise
gradient data
780(30CH)
CH4
Simultaneous
temperature rise
dead time
781(30DH)
CH4
Simultaneous
temperature rise
AT mode
selection
782(30EH)
CH4
Simultaneous
temperature rise
status
783(30FH)
CH4
Setting variation
rate limiter unit
time setting
784(310H)
All
Peak current
suppression
control group
setting
785(311H)
All
Sensor correction function selection
786(312H)
All
Temperature conversion completion flag
787(313H)
All
Function extension bit monitor
788(314H)
All
Sampling cycle monitor
789 to 1023
System area
(315H to
3FFH)
1024(400H)
All
Sampling cycle and function extension setting
1025(401H)
All
Control mode selection
1026(402H)
All
HOLD/CLEAR setting
1027 to 1039
System area
(403H to
40FH)
1040(410H)
CH1
System area
1041(411H)
CH1
System area
1042(412H)
CH1
System area
1043(413H)
CH1
System area
1044(414H)
CH1
Disturbance judgment position
1045(415H)
CH1
Set value return adjustment
1046(416H)
CH1
Feed forward control forced starting signal
1047(417H)
CH1
Feed forward value
1048(418H)
CH1
Feed forward value tuning selection
1049(419H)
CH1
Auto tuning error judgment time
1050(41AH)
CH1
Overshoot suppression level setting
1051(41BH)
CH1
Heater disconnection judgment mode
APPX
206
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
Derivative action
Derivative action
*1
selection
selection
System area
Simultaneous
temperature rise
group setting
System area
Simultaneous
temperature rise
gradient data
System area
Simultaneous
temperature rise
dead time
System area
Simultaneous
temperature rise
AT mode
selection
System area
Simultaneous
temperature rise
status
Setting variation
Setting variation
rate limiter unit
rate limiter unit
*1
time setting
time setting
System area
*14
*11
Default
value
Position-
proportional
control
System area
0
System area
0
System area
0
System area
0
System area
0
System area
0
Setting variation
0
rate limiter unit
*5
time setting
0
0
0
0
0
0
0
0
Open/close
20
output neutral
band setting
Control motor
10
time
Integration
1500
output limiter
setting
Valve operation
0
setting during
CPU module
STOP
System area
0
System area
0
System area
0
System area
0
System area
0
120
0
System area
0
Data
(1)
(2)
(3)
(4)
type
Setting
Setting
Setting
Setting
Setting
Monitor
Setting
Setting
Setting
Monitor
Monitor
Monitor
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
(5)