CH1 Close side transistor output flag
For details on this area, refer to the following:
Page 234 CH1 Transistor output flag
■Buffer memory address
The following shows the buffer memory address of this area.
*1
Buffer memory area name
CH Close side transistor output flag
CH Close side transistor output flag (in the Q compatible mode)
*1 In GX Works3, CH Cooling transistor output flag is displayed as the sample comment of CH Close side transistor output flag.
CH1 Self-tuning flag
The execution status of the self-tuning can be monitored in this area. For details on the self-tuning function, refer to the
following:
Page 47 Self-tuning Function
to
b15
b10 b9
0
0
0
0
0
Fixed to 0
One of the following values is stored in each bit:
• 0: OFF
• 1: ON
Bit
Flag name
b0
PID auto-correction
status
b1
Simultaneous
temperature rise
parameter correction
status
b2 to b7
(Fixed to 0)
b8
Self-tuning disable
status
to
b8
b7
b2
0
0
0
0
0
Fixed to 0
Description
This bit turns ON after PID constants are corrected by the
self-tuning.
This bit turns ON after the simultaneous temperature rise
*1
parameters
are corrected by the self-tuning.
(Not used)
This bit turns ON when the self-tuning was not able to be
executed.
CH1
CH2
410
610
712
713
b1
b0
0
Condition in which the bit turns OFF
This bit turns OFF after one of the following operations is
executed.
• When 'Setting/operation mode command' (Y1) is turned
from ON to OFF and the mode shifts to the setting mode
• When 'CH1 Unused channel setting' (Un\G502) is set to
Unused (1)
• When 'CH1 PID control forced stop command' (YC) is
turned from OFF to ON
• When 'CH1 Self-tuning setting' (Un\G548) is set to Do
not execute ST (0)
This bit turns OFF in the following cases as well.
• When the self-tuning has started by the change of the set
value (SV)
• When the temperature process value (PV) becomes out
of the stable state and the vibration ST has started
This bit turns OFF after one of the following operations is
executed.
• When 'Setting/operation mode command' (Y1) is turned
from ON to OFF and the mode shifts to the setting mode
• When 'CH1 Unused channel setting' (Un\G502) is set to
Unused (1)
• When 'CH1 PID control forced stop command' (YC) is
turned from OFF to ON
• When 'CH1 Self-tuning setting' (Un\G548) is set to Do
not execute ST (0)
This bit turns OFF when all the conditions that disable the
execution of the self-tuning are cleared.
For conditions that disable the execution of the self-tuning,
refer to the following:
Page 51 Conditions in which the self-tuning is not
executed
CH3
CH4
810
1010
714
715