Mitsubishi Electric MELSEC iQ-R Series User Manual page 182

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
929(3A1H)
CH3
System area
930(3A2H)
CH3
System area
931(3A3H)
CH3
Alert dead band
setting
932(3A4H)
CH3
Number of alert
delay
933(3A5H)
CH3
Alert 1 mode
setting
934(3A6H)
CH3
Alert 2 mode
setting
935(3A7H)
CH3
Alert 3 mode
setting
936(3A8H)
CH3
Alert 4 mode
setting
937(3A9H)
CH3
Loop
disconnection
detection
judgment time
938(3AAH)
CH3
Loop
disconnection
detection dead
band
939(3ABH)
CH3
Rate alarm alert output enable/disable setting
940(3ACH)
CH3
Rate alarm alert detection cycle
941(3ADH)
CH3
Rate alarm upper limit value
942(3AEH)
CH3
Rate alarm lower limit value
943(3AFH)
CH3
Auto tuning
mode selection
944(3B0H)
CH3
Auto tuning error
judgment time
945(3B1H)
CH3
During AT loop
disconnection
detection
function enable/
disable
946(3B2H)
CH3
AT bias
947(3B3H)
CH3
Automatic
backup setting
after auto tuning
of PID constants
948(3B4H)
CH3
Self-tuning
setting
949(3B5H)
CH3
Process value
(PV) scaling
function enable/
disable setting
950(3B6H)
CH3
Process value
(PV) scaling
upper limit value
951(3B7H)
CH3
Process value
(PV) scaling
lower limit value
APPX
180
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
Alert dead band
Alert dead band
*4
setting
setting
Number of alert
Number of alert
*4
delay
delay
Alert 1 mode
Alert 1 mode
*4
setting
setting
Alert 2 mode
Alert 2 mode
*4
setting
setting
Alert 3 mode
Alert 3 mode
*4
setting
setting
Alert 4 mode
Alert 4 mode
*4
setting
setting
System area
Loop
disconnection
detection
judgment time
System area
Loop
disconnection
detection dead
band
Auto tuning
Auto tuning
*4
mode selection
mode selection
Auto tuning error
Auto tuning error
*4
judgment time
judgment time
System area
During AT loop
disconnection
detection
function enable/
disable
*4
AT bias
AT bias
Automatic
Automatic
backup setting
backup setting
after auto tuning
after auto tuning
of PID
of PID constants
*4
constants
System area
Self-tuning
setting
Process value
Process value
(PV) scaling
(PV) scaling
function enable/
function enable/
*4
disable setting
disable setting
Process value
Process value
(PV) scaling
(PV) scaling
upper limit
upper limit value
*4
value
Process value
Process value
(PV) scaling
(PV) scaling
lower limit
lower limit value
*4
value
Default
value
Position-
proportional
control
Integration
1500
output limiter
*8
setting
Valve operation
0
setting during
CPU module
*8
STOP
Alert dead band
5
*8
setting
Number of alert
0
*8
delay
Alert 1 mode
0
*8
setting
Alert 2 mode
0
*8
setting
Alert 3 mode
0
*8
setting
Alert 4 mode
0
*8
setting
System area
480
System area
0
1
1
0
0
Auto tuning
0
*8
mode selection
Auto tuning error
120
*8
judgment time
System area
0
*8
AT bias
0
Automatic
0
backup setting
after auto tuning
of PID
*8
constants
System area
0
Process value
0
(PV) scaling
function enable/
*8
disable setting
Process value
0
(PV) scaling
upper limit
*8
value
Process value
0
(PV) scaling
lower limit
*8
value
Data
(1)
(2)
(3)
(4)
type
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents