Mitsubishi Electric MELSEC iQ-R Series User Manual page 188

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
1157(485H)
CH4
Disturbance
judgment
position
1158(486H)
CH4
Set value return
adjustment
1159(487H)
CH4
Feed forward
control forced
starting signal
1160(488H)
CH4
Feed forward
value
1161(489H)
CH4
Feed forward
value tuning
selection
1162(48AH)
CH4
Overshoot
suppression
level setting
1163(48BH)
CH4
Primary delay digital filter setting
1164(48CH)
CH4
Sensor correction function selection
1165(48DH)
CH4
Sensor correction value setting
1166(48EH)
CH4
Sensor two-point correction offset latch request
1167(48FH)
CH4
Sensor two-point correction gain latch request
1168(490H)
CH4
Sensor two-point correction offset value (measured value)
1169(491H)
CH4
Sensor two-point correction offset value (corrected value)
1170(492H)
CH4
Sensor two-point correction gain value (measured value)
1171(493H)
CH4
Sensor two-point correction gain value (corrected value)
1172(494H)
CH4
Number of moving averaging setting
1173 to 1999
System area
(495H to
7CFH)
2000(7D0H)
All
Heater disconnection/output off-time current error
detection delay count
2001(7D1H)
All
Heater disconnection correction function selection
2002(7D2H)
All
CT monitor method selection
2003(7D3H)
System area
2004(7D4H)
CH1
Heater disconnection alert setting
2005(7D5H)
CH1
Heater disconnection judgment mode
2006(7D6H)
System area
2007(7D7H)
CH2
Heater disconnection alert setting
2008(7D8H)
CH2
Heater disconnection judgment
mode
2009(7D9H)
System area
2010(7DAH)
CH3
Heater
disconnection
alert setting
2011(7DBH)
CH3
Heater
disconnection
judgment
mode
2012(7DCH)
System area
2013(7DDH)
CH4
Heater
disconnection
alert setting
2014(7DEH)
CH4
Heater
disconnection
judgment
mode
APPX
186
Appendix 3 Buffer Memory Areas
Heating-
cooling
control
Disturbance
judgment
*4
position
Set value return
*4
adjustment
Feed forward
control forced
*4
starting signal
Feed forward
*4
value
Feed forward
value tuning
*4
selection
Overshoot
suppression
*4
level setting
*13
*13
*13
*13
*13
*13
System area
*13
System area
*13
System area
*13
System area
*13
Mix control
Position-
proportional
control
Disturbance
System area
judgment
position
Set value return
System area
adjustment
Feed forward
System area
control forced
starting signal
Feed forward
System area
value
Feed forward
System area
value tuning
selection
Overshoot
Overshoot
suppression
suppression
*8
level setting
level setting
System area
*13
System area
System area
System area
System area
System area
System area
Heater
System area
disconnection
*13
alert setting
Heater
System area
disconnection
judgment
*13
mode
Heater
System area
disconnection
*13
alert setting
Heater
System area
disconnection
judgment
*13
mode
Default
Data
(1)
(2)
value
type
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
2
Setting
3
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
(3)
(4)
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents