Mitsubishi Electric MELSEC iQ-R Series User Manual page 207

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
758(2F6H)
CH3
Process value
(PV) scaling
lower limit value
759(2F7H)
CH3
Process value
(PV) scaling
upper limit value
760(2F8H)
CH3
Process value
(PV) scaling
value
761(2F9H)
CH3
Derivative action
selection
762(2FAH)
CH3
Simultaneous
temperature rise
group setting
763(2FBH)
CH3
Simultaneous
temperature rise
gradient data
764(2FCH)
CH3
Simultaneous
temperature rise
dead time
765(2FDH)
CH3
Simultaneous
temperature rise
AT mode
selection
766(2FEH)
CH3
Simultaneous
temperature rise
status
767(2FFH)
CH3
Setting variation
rate limiter unit
time setting
768(300H)
CH4
System area
769(301H)
CH4
System area
770(302H)
CH4
System area
771(303H)
CH4
System area
772(304H)
CH4
Manual reset
amount setting
773(305H)
CH4
Process value
(PV) scaling
function enable/
disable setting
774(306H)
CH4
Process value
(PV) scaling
lower limit value
775(307H)
CH4
Process value
(PV) scaling
upper limit value
776(308H)
CH4
Process value
(PV) scaling
value
Heating-
Mix control
cooling
control
Process value
Process value
(PV) scaling
(PV) scaling
lower limit
lower limit value
*1
value
Process value
Process value
(PV) scaling
(PV) scaling
upper limit
upper limit value
*1
value
Process value
Process value
(PV) scaling
(PV) scaling
*1
value
value
Derivative action
Derivative action
*1
selection
selection
System area
Simultaneous
temperature rise
group setting
System area
Simultaneous
temperature rise
gradient data
System area
Simultaneous
temperature rise
dead time
System area
Simultaneous
temperature rise
AT mode
selection
System area
Simultaneous
temperature rise
status
Setting variation
Setting variation
rate limiter unit
rate limiter unit
*1
time setting
time setting
Cooling
System area
proportional
band (Pc)
*1
setting
Cooling upper
System area
limit output
*1
limiter
Cooling control
System area
output cycle
*1
setting
Overlap/dead
System area
*1
band setting
Manual reset
Manual reset
*1
amount setting
amount setting
Process value
Process value
(PV) scaling
(PV) scaling
function enable/
function enable/
*1
disable setting
disable setting
Process value
Process value
(PV) scaling
(PV) scaling
lower limit
lower limit value
*1
value
Process value
Process value
(PV) scaling
(PV) scaling
upper limit
upper limit value
*1
value
Process value
Process value
(PV) scaling
(PV) scaling
*1
value
value
Default
Data
value
type
Position-
proportional
control
Process value
0
Setting
(PV) scaling
lower limit
*5
value
Process value
0
Setting
(PV) scaling
upper limit
*5
value
Process value
0
Monitor
(PV) scaling
*5
value
System area
0
Setting
System area
0
Setting
System area
0
Setting
System area
0
Setting
System area
0
Setting
System area
0
Monitor
Setting variation
0
Setting
rate limiter unit
*5
time setting
30
Setting
1000
Setting
*15
30
Setting
*16
300
0
Setting
System area
0
Setting
0
Setting
Process value
(PV) scaling
function enable/
*5
disable setting
Process value
0
Setting
(PV) scaling
lower limit
*5
value
Process value
0
Setting
(PV) scaling
upper limit
*5
value
Process value
0
Monitor
(PV) scaling
*5
value
Appendix 3 Buffer Memory Areas
(1)
(2)
(3)
(4)
(5)
A
APPX
205