Mitsubishi Electric MELSEC iQ-R Series User Manual page 186

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
1114(45AH)
CH4
Setting variation
rate limiter
(temperature
drop)
1115(45BH)
CH4
Direct/reverse
action setting
1116(45CH)
CH4
Adjustment
sensitivity (dead
band) setting
1117(45DH)
CH4
Manual reset
amount setting
1118(45EH)
CH4
AUTO/MAN
mode shift
1119(45FH)
CH4
MAN output
setting
1120(460H)
CH4
System area
1121(461H)
CH4
System area
1122(462H)
CH4
System area
1123(463H)
CH4
System area
1124(464H)
CH4
System area
1125(465H)
CH4
Derivative action
selection
1126(466H)
CH4
Setting variation
rate limiter unit
time setting
1127(467H)
CH4
System area
1128(468H)
CH4
System area
1129(469H)
CH4
System area
1130(46AH)
CH4
System area
1131(46BH)
CH4
Alert dead band
setting
1132(46CH)
CH4
Number of alert
delay
1133(46DH)
CH4
Alert 1 mode
setting
1134(46EH)
CH4
Alert 2 mode
setting
1135(46FH)
CH4
Alert 3 mode
setting
1136(470H)
CH4
Alert 4 mode
setting
APPX
184
Appendix 3 Buffer Memory Areas
Heating-
cooling
control
Setting variation
rate limiter
(temperature
*3
*3*4
drop)
System area
Adjustment
sensitivity (dead
*4
band) setting
Manual reset
*4
amount setting
AUTO/MAN
*4
mode shift
MAN output
*4
setting
Temperature
conversion
*5
setting
Cooling upper
limit output
*4
limiter
Cooling control
output cycle
*4
setting
Cooling method
*4
setting
Overlap/dead
*4
band setting
Derivative action
*4
selection
Setting variation
rate limiter unit
*4
time setting
Alert dead band
*4
setting
Number of alert
*4
delay
Alert 1 mode
*4
setting
Alert 2 mode
*4
setting
Alert 3 mode
*4
setting
Alert 4 mode
*4
setting
Mix control
Position-
proportional
control
Setting variation
Setting variation
rate limiter
rate limiter
(temperature
(temperature
*3
*3*8
drop)
drop)
Direct/reverse
Direct/reverse
*8
action setting
action setting
Adjustment
Adjustment
sensitivity (dead
sensitivity (dead
*8
band) setting
band) setting
Manual reset
System area
amount setting
AUTO/MAN
System area
mode shift
MAN output
System area
setting
System area
Temperature
conversion
*9
setting
System area
System area
System area
System area
Derivative action
System area
selection
Setting variation
Setting variation
rate limiter unit
rate limiter unit
*8
time setting
time setting
Open/close
output neutral
*8
band setting
Control motor
*8
time
Integration
output limiter
*8
setting
Valve operation
setting during
CPU module
*8
STOP
Alert dead band
Alert dead band
*8
setting
setting
Number of alert
Number of alert
*8
delay
delay
Alert 1 mode
Alert 1 mode
*8
setting
setting
Alert 2 mode
Alert 2 mode
*8
setting
setting
Alert 3 mode
Alert 3 mode
*8
setting
setting
Alert 4 mode
Alert 4 mode
*8
setting
setting
Default
Data
(1)
(2)
value
type
0
Setting
1
Setting
5
Setting
0
Setting
0
Setting
0
Setting
0
Setting
1000
Setting
*14
30
Setting
*15
300
0
Setting
0
Setting
0
Setting
0
Setting
20
Setting
10
Setting
1500
Setting
0
Setting
5
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
(3)
(4)
(5)