Mitsubishi Electric MELSEC iQ-R Series User Manual page 172

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
419(1A3H)
CH1
Sensor two-point correction offset latch completion
420(1A4H)
CH1
Sensor two-point correction gain latch completion
421 to 429
System area
(1A5H to
1ADH)
430(1AEH)
CH1
Set value (SV) setting
431(1AFH)
CH1
Proportional
band (P) setting
432(1B0H)
CH1
Integral time (I) setting
433(1B1H)
CH1
Derivative time (D) setting
434(1B2H)
CH1
Alert set value 1
435(1B3H)
CH1
Alert set value 2
436(1B4H)
CH1
Alert set value 3
437(1B5H)
CH1
Alert set value 4
438(1B6H)
CH1
Temperature process value (PV) for input with another analog module
439(1B7H)
CH1
System area
440(1B8H)
CH1
Memory's PID constants read command
441(1B9H)
CH1
Feed forward value memory read command
442 to 499
System area
(1BAH to
1F3H)
500(1F4H)
CH1
HOLD/CLEAR setting
501(1F5H)
CH1
Input range
502(1F6H)
CH1
Unused channel setting
503(1F7H)
CH1
Stop mode setting
504(1F8H)
CH1
Control output
cycle setting
505(1F9H)
CH1
Control response parameter
506(1FAH)
CH1
Temperature rise completion range setting
507(1FBH)
CH1
Temperature rise completion soak time setting
508(1FCH)
CH1
Upper limit
output limiter
509(1FDH)
CH1
Lower limit
output limiter
510(1FEH)
CH1
Output variation amount limiter
511(1FFH)
CH1
Upper limit setting limiter
512(200H)
CH1
Lower limit setting limiter
513(201H)
CH1
Setting variation rate limiter/setting variation rate limiter (temperature rise)
514(202H)
CH1
Setting variation rate limiter (temperature drop)
515(203H)
CH1
Direct/reverse
action setting
516(204H)
CH1
Adjustment sensitivity (dead band) setting
517(205H)
CH1
Manual reset amount setting
518(206H)
CH1
AUTO/MAN mode shift
519(207H)
CH1
MAN output setting
520(208H)
CH1
System area
521(209H)
CH1
System area
522(20AH)
CH1
System area
APPX
170
Appendix 3 Buffer Memory Areas
Heating-
Mix control
cooling
control
Heating proportional band (Ph)
setting
Cooling proportional band (Pc)
setting
Heating control output cycle setting
Heating upper limit output limiter
System area
*3
System area
Cooling upper limit output limiter
Cooling control output cycle setting
Default
value
Position-
proportional
control
0
0
0
Proportional
30
band (P) setting
240
60
0
0
0
0
0
System area
30
0
System area
0
0
2(TCTRT)
7(TCRT)
0
1
*14
System area
30
*15
300
0
1
0
System area
1000
0
System area
0
1300(TCTRT
)
6000(TCRT)
0(TCTRT)
-2000(TCRT)
*2
0
0
Direct/reverse
1
action setting
5
System area
0
System area
0
System area
0
System area
1000
*14
System area
30
*15
300
Data
(1)
(2)
(3)
(4)
type
Monitor
Monitor
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
(5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60tctrt2tt2R60tcrt4R60tctrt2tt2bwR60tcrt4bw

Table of Contents