Mitsubishi Electric MELSEC iQ-R Series User Manual page 173

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
523(20BH)
CH1
System area
524(20CH)
CH1
System area
525(20DH)
CH1
Derivative action selection
526(20EH)
CH1
Setting variation rate limiter unit time setting
527(20FH)
CH1
System area
528(210H)
CH1
System area
529(211H)
CH1
System area
530(212H)
CH1
System area
531(213H)
CH1
Alert dead band setting
532(214H)
CH1
Number of alert delay
533(215H)
CH1
Alert 1 mode setting
534(216H)
CH1
Alert 2 mode setting
535(217H)
CH1
Alert 3 mode setting
536(218H)
CH1
Alert 4 mode setting
537(219H)
CH1
Loop
disconnection
detection
judgment time
538(21AH)
CH1
Loop
disconnection
detection dead
band
539(21BH)
CH1
Rate alarm alert output enable/disable setting
540(21CH)
CH1
Rate alarm alert detection cycle
541(21DH)
CH1
Rate alarm upper limit value
542(21EH)
CH1
Rate alarm lower limit value
543(21FH)
CH1
Auto tuning mode selection
544(220H)
CH1
Auto tuning error judgment time
545(221H)
CH1
During AT loop
disconnection
detection
function enable/
disable
546(222H)
CH1
AT bias
547(223H)
CH1
Automatic backup setting after auto tuning of PID constants
548(224H)
CH1
Self-tuning
setting
549(225H)
CH1
Process value (PV) scaling function enable/disable setting
550(226H)
CH1
Process value (PV) scaling upper limit value
551(227H)
CH1
Process value (PV) scaling lower limit value
552(228H)
CH1
Peak current
suppression
control group
setting
553(229H)
CH1
Simultaneous
temperature rise
group setting
Heating-
Mix control
cooling
control
Cooling method setting
Overlap/dead band setting
System area
System area
System area
System area
System area
System area
Default
Data
value
type
Position-
proportional
control
System area
0
Setting
System area
0
Setting
System area
0
Setting
0
Setting
Open/close
20
Setting
output neutral
band setting
Control motor
10
Setting
time
Integration
1500
Setting
output limiter
setting
Valve operation
0
Setting
setting during
CPU module
STOP
5
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
480
Setting
0
Setting
1
Setting
1
Setting
0
Setting
0
Setting
0
Setting
120
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
Appendix 3 Buffer Memory Areas