Mitsubishi Electric MELSEC iQ-R Series User Manual page 195

Temperature control module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address:
CH
Setting details
Decimal
Standard
(hexadeci
control
mal)
60(3CH)
CH1
Loop
disconnection
detection dead
band
61(3DH)
CH1
Unused channel setting
62(3EH)
CH1
Memory's PID constants read command
63(3FH)
CH1
Automatic backup setting after auto tuning of PID constants
64(40H)
CH2
Input range
65(41H)
CH2
Stop mode setting
66(42H)
CH2
Set value (SV) setting
67(43H)
CH2
Proportional
band (P) setting
68(44H)
CH2
Integral time (I) setting
69(45H)
CH2
Derivative time (D) setting
70(46H)
CH2
Alert set value 1
71(47H)
CH2
Alert set value 2
72(48H)
CH2
Alert set value 3
73(49H)
CH2
Alert set value 4
74(4AH)
CH2
Upper limit
output limiter
75(4BH)
CH2
Lower limit
output limiter
76(4CH)
CH2
Output variation amount limiter
77(4DH)
CH2
Sensor correction value setting
78(4EH)
CH2
Adjustment sensitivity (dead band)
setting
79(4FH)
CH2
Control output
cycle setting
80(50H)
CH2
Primary delay digital filter setting
81(51H)
CH2
Control response parameter
82(52H)
CH2
AUTO/MAN mode shift
83(53H)
CH2
MAN output setting
84(54H)
CH2
Setting variation rate limiter/setting
variation rate limiter (temperature
*10
rise)
85(55H)
CH2
AT bias
Heating-
Mix control
cooling
control
System area
Stop mode
*3
setting
Set value (SV)
*3
setting
Heating
Heating
proportional
proportional
band (Ph) setting
band (Ph)
*3
setting
Integral time (I)
*3
setting
Derivative time
*3
(D) setting
Alert set value
*3
1
Alert set value
*3
2
Alert set value
*3
3
Alert set value
*3
4
Heating upper
Heating upper
limit output
limit output
*3
limiter
limiter
System area
Output variation
*3
amount limiter
Adjustment
sensitivity (dead
*3
band) setting
Heating control
Heating control
output cycle
output cycle
*3
setting
setting
Control
response
*3
parameter
AUTO/MAN
*3
mode shift
MAN output
*3
setting
Setting variation
rate limiter/
setting variation
rate limiter
(temperature
*3*10
rise)
*3
AT bias
Default
Data
value
type
Position-
proportional
control
0
Setting
0
Setting
0
Setting
0
Setting
2(TCTRT)
Setting
7(TCRT)
Stop mode
1
Setting
setting
Set value (SV)
0
Setting
setting
Proportional
30
Setting
band (P) setting
Integral time (I)
240
Setting
setting
Derivative time
60
Setting
(D) setting
Alert set value 1
0
Setting
Alert set value 2
0
Setting
Alert set value 3
0
Setting
Alert set value 4
0
Setting
System area
1000
Setting
0
Setting
System area
0
Setting
0
Setting
Adjustment
5
Setting
sensitivity (dead
band) setting
*15
System area
30
Setting
*16
300
0
Setting
Control
0
Setting
response
parameter
System area
0
Setting
System area
0
Setting
Setting variation
0
Setting
rate limiter/
setting variation
rate limiter
(temperature
*10
rise)
AT bias
0
Setting
Appendix 3 Buffer Memory Areas
(1)
(2)
(3)
(4)
(5)
A
APPX
193