01.02
Remedy
Program continua-
tion by
400 010
Explanation
Response
Remedy
Program continua-
tion by
400 011
Explanation
Response
Remedy
Program continua-
tion by
400 013
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Modify user program.
Power ON
Arithmetic error in network of user program: [No.] [type]
Check the user program in the specified network.
[No.]
Network number
Type 1:
Division by zero with normal arithmetic
Type 2:
Floating point error
PLC stop
Modify user program.
Power ON.
Permitted number of subroutine levels in network exceeded [No.]
[No.]
Network number
Check the user program in the specified network.
PLC stop
Modify user program.
Power ON
PLC user program faulty
The PLC user program in the control system is defective or missing.
PLC stop
Reload PLC user program.
Power ON