SINUMERIK 802S/802C (DG)
Block preparation in NC is aborted
Check machine configuration (one geometry axis missing).
Press the RESET key to clear the alarm. Restart part program.
First drilling depth incorrectly defined
LCYC83
Block preparation in NC is aborted
Alter the value for the first drilling depth (the first drilling depth is opposite to
the total drilling depth).
Press the RESET key to clear the alarm. Restart part program.
Reference plane incorrectly defined
LCYC75
LCYC82
LCYC83
LCYC84
LCYC840
LCYC85
Block preparation in NC is aborted
Check parameters R101, R103, R104:
R103=R104 or R103 is not between R101 and R104.
Press the RESET key to clear the alarm. Restart part program.
No spindle direction programmed
LCYC840
Block preparation in NC is aborted
Value of parameter R107 is greater than 4 or less than 3.
Press the RESET key to clear the alarm. Restart part program.
Number of holes is zero
LCYC60
LCYC61
Block preparation in NC is aborted
Parameter R119 = 0.
Press the RESET key to clear the alarm. Restart part program.
Milling cutter radius too big
LCYC75
Block preparation in NC is aborted
6FC5598-3AA20-0BP2