Download Print this page

Siemens SINUMERIK 802S Diagnostics Manual page 48

Hide thumbs Also See for SINUMERIK 802S:

Advertisement

1 Alarms
Program continua-
tion by
14 800
Explanation
Response
Remedy
Program continua-
tion by
14 820
Explanation
Response
Remedy
Program continua-
tion by
14 830
Explanation
Response
1-48
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 programmed path speed less or equal to zero
%1 = Channel number
%2 = Block number, label
A negative F value has been programmed in conjunction with the G functions
G94, G95 or G96. The path velocity may be programmed in the range from
0.001 to 999 999.999 [mm/min, mm/rev, degrees/min, degrees/rev] for the
metric input system and from 0.000 1 to 39 999.999 9 [inch/min, inch/rev] for
the inch input system.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Program the path velocity (geometrical sum of the velocity components of the
geometry axes involved) within the limits specified above.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 negative value for maximum spindle speed pro-
grammed with constant cutting speed
%1 = Channel number
%2 = Block number, label
You can program a maximum spindle speed for the function "Constant cutting
speed G96" using the key word LIMS=... The value range is between
0.1 - 999 999.9 [rev/min].
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Program the maximum spindle speed for the constant cutting speed within the
limits specified above. The key word LIMS is modal and can be written either
in front of the block with the selection of the constant cutting speed or in the
block.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 wrong feed type selected
%1 = Channel number
%2 = Block number, label
G97 has been programmed in the displayed block although G96 (or already
G97) has not been activated.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
6FC5598-3AA20-0BP2