1 Alarms
17 180
Explanation
Response
Remedy
Program continua-
tion by
17 190
Explanation
Response
Remedy
Program continua-
tion by
17 200
Explanation
Response
1-68
Channel %1 block %2 illegal D number
%1 = Channel number
%2 = Block number, label
In the displayed block, a D number (edge number) is accessed which is not
initialized and therefore does not exist.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Check tool call in NC part program:
Are the correct edge number (D number) programmed?
If no edge number is specified, D1 is automatically active.
All tool parameters defined?
The dimensions of the tool edge must have been entered in advance either
via the operator panel or the V24 interface.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 illegal T number
%1 = Channel number
%2 = Block number, label
In the displayed block, a T number (tool number) is accessed which is not
initialized and therefore does not exist.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Check tool call in NC part program:
Is the correct tool number T... programmed?
Tool parameters P1 - P25 defined?
The dimensions of the tool edge must have been entered in advance either
via the operator panel or the V24 interface.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2: cannot delete an active tool
%1 = Channel number
%2 = Block number, label
You have tried to remove the tool data for a workpiece currently being ma-
chined from the part program. Tool data for workpieces currently being ma-
chined must not be deleted. This applies both to the tool preselected and
changed by T, and for tools for which a constant wheel circumferential speed
or tool monitoring is active.
Alarm display.
Interface signals are set.
6FC5598-3AA20-0BP2