Download Print this page

Siemens SINUMERIK 802S Diagnostics Manual page 30

Hide thumbs Also See for SINUMERIK 802S:

Advertisement

1 Alarms
10 860
Explanation
Response
Remedy
Program continua-
tion by
10 870
Explanation
Response
Remedy
Program continua-
tion by
10 880
Explanation
1-30
Channel %1 block %2 feed rate not programmed
%1 = Channel number
%2 = Block number, label
An interpolation type other than G00 (rapid traverse) is active in the displayed
block. No F value programmed.
Alarm display.
Interface signals are set.
NC Start inhibited.
Program the feed value with respect of the interpolation type used.
G94 and G97: The feed is programmed under address F in [mm/min] or
[m/min].
G95: The feed is programmed as a revolutional feedrate in [mm/rev] un-
der address F.
G96: The feed is programmed as a cutting speed under address S in
[m/min]. It results from the current spindle speed.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 facing axis not defined
%1 = Channel number
%2 = Block number, label
When the constant cutting speed is selected using the function G96, the spindle
speed is controlled via the position of the facing axis such that the cutting
speed programmed under S [mm/min] results at the tool edge.
In the channel-specific MD DIAMETER_AX_DEF[n,m]=x (n .. channel
index, m .. spindle index, x .. axis name), the name of the facing axis [string]
can be specified for each of the 5 spindles which is used for speed calculation.
[
S
m / min 1000
G96
S [1/min] =
[
D
mm
facing axis
Alarm display.
Interface signals are set.
NC Start inhibited.
Enter the name of the facing axis in the channel-specific machine data
DIAMETER_AX_DEF for the spindles used.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 too many empty blocks between two traversing
blocks when inserting chamfer or radius
%1 = Channel number
%2 = Block number, label
Too many blocks without contour information are programmed between two
blocks which contain contour elements and which are to be linked with a cham-
fer or a radius (CHF, RND).
6FC5598-3AA20-0BP2
]
]
⋅ π
© Siemens AG 2002 All Rights Reserved
01.02
SINUMERIK 802S/802C (DG)

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Sinumerik 802c