01.02
16 916
Explanation
Response
Remedy
Program continua-
tion by
16 918
Explanation
Response
Remedy
Program continua-
tion by
16 919
Explanation
Response
Remedy
Program continua-
tion by
16 920
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Channel %1 reposition: action %2 not allowed in the current state
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
Repositioning of block execution is currently not possible. Mode change can
therefore not be carried out.
The 2nd parameter described the action recommended to use for repositioning.
Alarm display.
Continue the program to an NC block which can be repositioned, or modify
part program.
Press the Clear key to clear the alarm. No further operation required.
Channel %1: for action %2 needs reset in all channel.
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
To execute the action, the channel must be in initial state!
(e.g. for loading _N_INITIAL
Alarm display.
Press the RESET
.
key
Press the Clear key to clear the alarm. No further operation required.
Channel %1 action %2 is not allowed, because of an alarm
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
Action %2 cannot be executed due to an alarm or the channel is in error condi-
tion.
Alarm display.
Press the RESET
.
key
Press the Clear key to clear the alarm. No further operation required.
Channel %1 action %2 is already in enabled
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
An identical action is still being executed.
Alarm display.
Wait until the previous operation is completed and then repeat the action..
Press the Clear key to clear the alarm. No further operation required.