01.02
Program continua-
tion by
10 931
Explanation
Response
Remedy
Program continua-
tion by
10 932
Explanation
Response
Remedy
Program continua-
tion by
10 933
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 error in programmed stock removal contour
%1 = Channel number
%2 = Block number, label
The following errors are contained in the stock removal program (LCYC 95)
for the contour:
full circle
intersecting contour elements
wrong start position
Alarm display.
Interface signals are set.
NC Start inhibited.
Correct the errors mentioned above in the program for the contour to be ma-
chined.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 preparation of contour has been restarted
%1 = Channel number
%2 = Block number, label
The stock removal cycle LCYC 95 has been interrupted during the preparation
phase of the stock removal contour.
Alarm display.
Interface signals are set.
NC Start inhibited.
Do not admit interruption during the contour preparation in the stock removal
cycle LCYC 95.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 contour program contains too few contour blocks
%1 = Channel number
%2 = Block number, label
The program in which the stock removal contour is programmed contains less
than 3 blocks with movements in both axes in the machining plane. The stock
removal cycle (LCYC 95) has been canceled.
Alarm display.
Interface signals are set.
NC Start inhibited.
Enlarge the program with the stock removal contour to at least 3 NC blocks
with axis movements in both axes of the current machining plane.
Press the RESET key to clear the alarm. Restart part program.