01.02
4 111
Explanation
Response
Remedy
Program continua-
tion by
4 230
Explanation
Response
Remedy
Program continua-
tion by
4 310
Explanation
Response
Remedy
Program continua-
tion by
4 400
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
PLC cycle increased to %1 ms
The PLC cycle divider has not been set to an integer multiple of the IPO cycle
divider.
The divider (MD 10 074 PLC_IPO_TIME_RATIO) has been increased.
Alarm display.
Adapt machine data.
Power ON
Channel %1 data alteration from external not possible in current channel
state
%1 = Channel number
These data may not be entered during part program execution (e.g. setting data
for spindle speed limitation or for dry run feed).
Alarm display.
The data to be entered must be altered before starting the part program.
Press the Clear key to clear the alarm. No further operation required.
Declaration in machine data %1 index %2 is not allowed
%1 = String: MD identifier
%2 = Index in MD array
The values of the machine data in the array must be arranged in ascending
order.
NC not ready for operation.
NC Stop at alarm.
NC Start inhibited.
Alarm display.
Interface signals are set.
Correct MD
Press the RESET key to clear the alarm. Restart part program.
Machine data alteration will cause reorganization of buffered memory
(loss of data!)
An MD has been altered which configures the buffered memory. An NCK boot
with the altered data will reorganize the buffered memory and thus result in a
loss of all buffered user data (part programs, tool data, GUD, LEC, ..).
Alarm display.
If the control system contains user data which have not yet been backed up,
these data must be saved before the next NCK boot. The reorganization of the
memory can be avoided by resetting the altered MD to the value during the last
boot manually.
Press the Clear key to clear the alarm. No further operation required.