1 Alarms
Program continua-
tion by
14 012
Explanation
Response
Remedy
Program continua-
tion by
14 013
Explanation
Response
Remedy
Program continua-
tion by
14 014
Explanation
Response
Remedy
Program continua-
tion by
1-42
1.
Check the subroutine name in the calling program.
2.
Check the name of the called program
3.
Check whether the program has been transferred into the NC memory.
4.
Check options or upgrade/enable.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 lowest subroutine level exceeded
%1 = Channel number
%2 = Block number, label
The maximum nesting depth of 4 program levels has been exceeded.
Subroutines that have a maximum nesting depth of 3 subroutines can be called
from the main program.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Modify machining program such that the nesting depth is reduced, e.g. use the
editor to copy a subroutine of the next nesting depth into the calling program
and remove the call for this subroutine. This will reduce the nesting depth by
one program level.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 number of subroutine passes invalid
%1 = Channel number
%2 = Block number, label
When a subroutine is called, the programmed number of passes P is either zero
or negative.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Program a number of passes between 1 and 9 999.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 selected program or access permission not available
%1 = Channel number
The selected part program is not in NC memory.
Alarm display.
Reload the desired program into the NC memory or check the name of the
directory (workpiece overview) and correct it.
Press the Clear key to clear the alarm. Restart part program.