SINUMERIK 802S/802C (DG)
Channel %1 block %2 label defined repeatedly
%1 = Channel number
%2 = Block number, label
The label of this block exists already.
If you compile the NC program offline, the entire program is compiled block
by block. Multiple designations are detected with 100 % safety, what in the
case of online compilation is not necessarily the case. (In this case, only the
current program execution is compiled, i.e. program branches that are not cur-
rently passed will also not be checked and can therefore contain programming
errors).
Alarm display.
Interface signals are set.
Corrected block.
Press NC Stop and select the Corrected Block function using the CORRECT
PROGRAM. softkey. The correction pointer is positioned on the block in
which the displayed label occurs for the second time.
Use the editor to browse the part program to find out where the searched des-
ignation occurs for the first time, and alter one of the two names.
Press NC START to clear the alarm and continue program execution.
Channel %1 block %2 unknown G function %3 used
%1 = Channel number
%2 = Block number, label
%3 = Source string
A non-defined G function has been programmed in the displayed block.
Alarm display.
Interface signals are set.
Use the Programming Instructions of the machine manufacturer to decide
whether the displayed G function is generally not available or not possible.
Remove the G function from the part program or program the function call
with respect of the Programming Instructions of the machine manufacturer.
Press NC START to clear the alarm and continue program execution.
Channel %1 block %2 access permission level %3 is not valid
%1 = Channel number
%2 = Block number, label
%3 = Source string
The desired access level has not been set. The desired protection class is out of
the admissible value range.
Alarm display.
Interface signals are set.
Remove the respective string from the program.
Press NC START to clear the alarm and continue program execution.
6FC5598-3AA20-0BP2
1 Alarms
1-39